1.
Clinics in Orthopedic Surgery ; : 449-455, 2021.
Article in English | WPRIM | ID: wpr-914097

ABSTRACT

Background@#Dual SC screw (DSCS) is a unique concept internal fixation device consisting of a sliding screw and barrel assembly that enables compression force to be applied to the femoral neck fracture side. There are two types of barrels: a thread barrel and a plate barrel that has a one-holed side plate to prevent varus deformity. We report clinical results of the application of a DSCS with combined use of a thread barrel screw as an anti-rotational screw and a plate barrel screw as a compression hip screw. @*Methods@#We used DSCS for femoral neck fractures in 196 hip joints of 190 patients between November 2005 and June 2017. Among them, 70 hips in 66 patients (13 men and 53 women; mean age, 73.2 years) were followed up for at least 24 months. There were 53 nondisplaced fractures (Garden’s classification stage 1 or 2) and 17 displaced fractures (stage 3 or 4). We evaluated the postoperative walking ability of the patients who were followed up for at least 24 months and examined details of all complications. @*Results@#The mean follow-up period was 37.4 months (range, 24–144 months). Forty-two (64%) out of the 66 patients who were followed up for at least 2 years were able to walk independently with or without a cane. The incidence of complications was 11.5% in nondisplaced fractures and 17.5% in displaced fractures, and arthroplasty was required in 5.8% and 5.0%, respectively. The most frequent complication was secondary displacement including cutout and shortening of the femoral neck, but no implants showed varus displacement. @*Conclusions@#The application of DSCS for the treatment of femoral neck fractures had satisfactory results. The complication rate was low, and there was no postoperative varus displacement of DSCS in either displaced or nondisplaced fractures. We suggest DSCS is a reliable option for both displaced and nondisplaced femoral neck fractures.

2.
Clinics in Orthopedic Surgery ; : 554-557, 2020.
Article in English | WPRIM | ID: wpr-831961

ABSTRACT

To reduce the stress on the medial tibial cortex and to decrease the risk of fracture, a varus cut of the tibia appears to be a reasonable alternative to the orthogonal cut by conventional methods. We present a new instrument and procedure, which enables a varus tibial cut for Oxford unicompartmental knee arthroplasty. We used a custom-made, slidable fixator instead of the standard fixator to set the extramedullary rod on the leg. We also made a numeric formula and a chart to arrange the varus cutting angle using the length of the mediolateral shift of the distal end and the longitudinal extension length of the extramedullary tibial rod. A varus cut up to 4.5° can be controlled. This technique is a simple and useful means of obtaining a varus tibial cut for Oxford unicompartmental knee arthroplasty.

SELECTION OF CITATIONS
SEARCH DETAIL